Separate primary fixing from secondary retention
The primary mount supports the fixture in normal use. A suitable secondary retention arrangement addresses the object if the primary fixing fails. The two functions need a deliberate installation design; adding a tether to the same compromised fixing may not create independence.
Record the fixture before specifying a net
Collect the complete weight, dimensions, shape and photographs from more than one direction. Identify removable parts, accessories and mounting geometry. Record the environment, including corrosion, vibration, temperature and inspection access.
Review the structural connection
Confirm an appropriate independent supporting point and the route of the retention connection. Consider clearance, possible movement and any interference with the fixture’s operation. Installation should follow the exact manufacturer instructions and the site’s engineering review.
Inspect the whole assembly
Include the primary fixing, enclosure or sling, connecting components, anchor and supporting structure. Record damage, wear, corrosion or changes in fit. Do not rely on secondary retention as a reason to leave damaged primary fixtures in service.
Avoid generic capacity assumptions
A material description or a product-family name does not establish the capacity of an installed assembly. Verify the selected model, fit and documented configuration. Confirm how a retained object would be isolated and recovered after an event.
Turn the review into a product enquiry
Send PSC the task photographs, tool inventory and weights, fixture details or opening dimensions. Include the operating environment, required quantity and delivery location so the appropriate product configuration can be reviewed.